Shelly Plus 1PM UL
Short description
The Shelly Plus 1PM UL is a UL-certified small form factor smart switch with power measurement, which allows remote control of electric appliances through a mobile phone, tablet, PC, or home automation system. It can work standalone in a local Wi-Fi network or it can also be operated through cloud home automation services.
The Shelly Plus 1PM UL can be accessed, controlled and monitored remotely from any place where the User has internet connectivity, as long as the device is connected to a Wi-Fi router and the Internet.
It can be retrofitted into standard electrical wall boxes, behind power sockets and light switches or other places with limited space.
The Shelly Plus 1PM UL has embedded Web Interface which can be used to monitor and control the device, as well as adjust its settings.
Device identification
Device name: Shelly Plus 1PM UL
Device model: SNSW-001P15UL
Device SSID: ShellyPlus1PM-XXXXXX
Main applications
Residential
MDU (Multi Dwelling Units - apartments, condominiums, hotels, etc.)
Light commercial (small office buildings, small retail/restaurant/gas station, etc.)
Government/municipal
University/college
Integrations
Amazon Alexa supported capabilities
Yes
Google Smart Home supported traits
Yes
Samsung SmartThings supported capabilities
Yes
Simplified internal schematics
Device electrical interfaces
Inputs
1 switch/button input on screw terminal: SW
5 power supply inputs on screw terminals: 2 N (+) and 3 L (Ʇ)
Outputs
1 relay output with power measurement on screw terminal: O
Add-on interface
Shelly proprietary serial interface
⚠CAUTION! High voltage on the add-on interface when the Device is powered!
Connectivity
Wi-Fi
Bluetooth
Safety features
Overheating protection
Overvoltage protection
Overcurrent protection
Overpower protection
Supported load types
Resistive (incandescent bulbs, heating devices)
Capacitive (capacitor banks, electronic equipment, motor start capacitors)
Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)
User interface
Inputs
-
One (Reset) button
Press and hold for 5 seconds to enable Device access point and Bluetooth connection.
Press and hold for 10 seconds to factory reset the Device.
Outputs
-
LED (monocolor) indication
AP (Access Point) enabled and Wi-Fi disabled:
1 secondON
/ 1 secondOFF
Wi-Fi enabled, but not connected to a Wi-Fi network:
1 secondON
/ 3 secondsOFF
Connected to a Wi-Fi network:
ConstantlyON
Cloud is enabled, but not connected:
1 secondON
/5 secondsOFF
Connected to Shelly Cloud:
ConstantlyON
OTA (Over the Air Update):
½ secON
/ ½ secondOFF
Button pressed and held for 5 seconds:
½ secondON
/ ½ secondOFF
Button presses and held for 10 seconds:
¼ secondON
/ ¼ secondOFF
The list above starts with the initial device status and the lowest priority. Every next state cancels the previous one.
Specifications
Type |
Value |
---|---|
Physical | |
Size (HxWxD): |
37x42x16 / 1.46x1.65x0.63 |
Weight: |
27 g / 0.95 oz |
Mounting: |
Wall console |
Screw terminals max torque: |
0.4 Nm / 3.5 lbin |
Conductor cross section: |
0.5 to 1.5 mm² / 20 to 14 AWG |
Conductor stripped length: |
5 to 6 mm / 0.20 to 0.24 in |
Shell material: |
Plastic |
Color: |
Red |
Environmental | |
Ambient temperature: |
-20 °C to 40 °C / -5 °F to 105 °F |
Humidity |
30 % to 70 % RH |
Max. altitude |
2000 m / 6562 ft |
Electrical | |
Power supply: |
|
Power consumption: |
< 1.2 W |
Output circuits ratings | |
Max switching voltage AC: |
240 V (Single wire) |
Max switching voltage DC: |
30 V |
Max switching current AC: |
15 A |
Max switching current DC: |
10 A |
Sensors, meters | |
Internal-temperature sensor: |
Yes |
Voltmeter (AC) |
Yes |
Ammeter (AC) |
Yes |
Radio | |
RF band: |
2400 - 2495 MHz |
Max. RF power: |
<20 dBm |
Wi-Fi protocol: |
802.11 b/g/n |
Wi-Fi Range: |
Up to 30 m / 100 ft indoors and 50 m / 160 ft outdoors |
Bluetooth Protocol: |
4.2 |
Bluetooth Range: |
Up to 10 m / 33 ft indoors and 30 m / 100 ft outdoors |
MCU | |
CPU: |
ESP32-U4WDH |
Flash: |
4 MB |
Firmware capabilities | |
Schedules: |
20 |
Webhooks (URL actions): |
20 with 5 URLs per hook |
Scripting: |
Yes |
MQTT: |
Yes |
CoAP: |
No |
Basic wiring diagrams
110-240 VAC power supply Resistive load |
110-240 VAC power supply Inductive load and RC snubber |
24-30 VDC power supply
Resistive load |
24-30 VDC power supply
Inductive load and RC snubber |
Legend
Terminals |
Wires |
||
---|---|---|---|
O |
Load circuit output terminal |
+ |
24 - 30 VDC positive wire |
SW |
Switch (controlling O) input terminal |
N |
Neutral wire |
L |
Live (110-240 V) terminal |
GND |
24 - 30 VDC ground wire |
N |
Neutral terminal |
|
|
+ |
24 - 30 VDC positive terminal |
|
|
Ʇ |
24 - 30 VDC ground terminal |
Troubleshooting
Your device is overheating.
Make sure you are not using the L and N device terminals as bridges. Using them as bridges doubles the current through them which leads to overheating. Using the terminals as bridges in only available with low currents, so that the total current does not exceed 15 A.
Make sure the ambient temperature does not exceed 40 °C / 105 °F. If placed in confined space Shelly Plus 1PM may increase the ambient temperature above the allowed limits. Ensure ventilation of the Device.
Web Interface guide
Read the Shelly Plus 1PM, 1PM UL web interface guide
Components and APIs
Printed user guide
Shelly Plus 1PM UL bilingual printed user and safety guide.pdf