Wave 2PM

Wave 2PM (EU)

Note: The product line known as "Shelly Qubino Wave" will now be referred to as "Shelly Wave". This name change will not impact the functionality of any devices. The only modification will be the use of the new name in all future documentation.

Device identification

Device name: Wave 2PM
EU Part number/Ordering Code: QNSW-002P16EU
Z-Wave Product type ID: 0x0002
Z-Wave Product ID: 0x0081
Z-Wave Manufacturer: Shelly Europe Ltd.
Z-Wave Manufacturer ID: 0x0460

Terminology

  • Device - In this document, the term “Device” is used to refer to the Wave 2PM device.

  • Gateway - A Z-Wave® gateway, also referred to as a Z-Wave® controller, Z-Wave® main controller, Z-Wave® primary controller, or Z-Wave® hub, etc., is a device that serves as a central hub for a Z-Wave® smart home network. The term “gateway” is used in this document.

  • S button - The Z-Wave® Service button, which is located on Z-Wave® devices and is used for various functions such as adding (inclusion), removing (exclusion), and resetting the device to its factory default settings. The term "S button" is used in this document.

Short description

The Wave 2PM (Device) is a single product that enables remote control of two electrical devices such as bulbs, ceiling fans, and IR heaters. It switches (on/off) two independent loads and measures their power consumption separately and in total. The Device is compatible with switches (default) and push-buttons.

Switch connected to input terminal SW (SW1)

If the SW (SW1) is configured as a switch (default), each toggle of the switch will change the output state O (O1) to the opposite state - ON, OFF, ON, etc.

  • Change switch position once: Change the state of the output state O (O1) to the opposite one and send command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association)

Switch connected to input terminal SW2

If the SW (SW1) is configured as a switch (default), each toggle of the switch will change the output state O2 to the opposite state - ON, OFF, ON, etc.

  • Change switch position once: Change the state of the output state O2 to the opposite one and send command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association)

Main applications

  • Residential

  • MDU (Multi Dwelling Units - apartments, condominiums, hotels, etc.)

  • Light commercial (small office buildings, small retail/restaurant/gas station, etc.)

  • Government/municipal

  • University/college

Integrations

Shelly Qubino Wave devices are developed on the world's leading technology for smart homes – Z-Wave.

This means Shelly Qubino Wave works with all certified gateways supporting Z-Wave communication protocol.

To make sure the functions of Shelly Qubino Wave products are supported on your gateway, we are regularly executing compatibility tests of our devices with different Z-Wave gateways.

Simplified internal schematics

Shelly Plus 2PM internal schematics

Device electrical interfaces

Inputs

  • 2 switch/button input on screw terminal

  • 3 power supply inputs on screw terminals: N (+) and L (?)

Outputs

  • 2 relay output with power measurement on screw terminal

Connectivity

Z-Wave - Unsecure, S0 Security, S2 Unauthenticated Security, S2 Authenticated Security

Safety features

Overheat protection

  • switch off its own relay

  • sends the Notification Report to the Gateway (Overheat detected)

  • the led lights react as specified above (check blinking mode for Overheat detected)

Any of next activities reset this alarm: power cycle, short press on S button, press any switch-push button connected to any SW (SW, SW1, SW2, …) terminal.

NOTE: The Overheat protection is always active and cannot be disabled.
Additional description above under chapter Notification for Overheat detected.

Over-current Protection

Device has internal Over-current protection. If the current exceeds 16A+10% (Max switching current +10%) for more than 5s, the Device will:

  • switch off its own relay

  • sends the Notification Report to the Gateway (Over-current detected)

  • the led lights react as specified above (check blinking mode for Over-current detected)

Any of next activities reset this alarm: power cycle, short press on S button, press any switch-push button connected to any SW (SW, SW1, SW2, …) terminal.

NOTE: The Over-current protection is always active and cannot be disabled.
Additional description above under chapter Notification for Over-current detected.

Supported load types

  • Resistive (incandescent bulbs, heating devices)

  • Capacitive (capacitor banks, electronic equipment, motor start capacitors)

  • Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)

User interface

S button and operating modes

  1. Normal mode

  2. Setting in progress mode

  3. Setting mode (with S button)

    • Settings mode is required to start desired procedure for example: adding (inclusion), removing (exclusion), factory reset etc. It has a limited time of operation. After the procedure in Setting mode is concluded, the Device goes automatically into Normal mode.

    • Entering to Setting mode:

      • Quickly press and hold the S button on the Device until the LED turns solid blue

      • An additional quick press on the S button means menu change in infinite loop

      • Menu LED status has a timeout of 10s before entering again into Normal state

S button’s functions

  • Manually adding the Device to a Z-Wave network

  • Manually removing the Device from a Z-Wave network

  • Factory Reset the Device

LED Signalisation

Click to see LED signalisation
Normal mode

Removed/Excluded

The LED will be blinking blue in Mode 1 for 10 min after every power cycle and 10 min after S button pressed.

Added/Included

The LED will be blinking green in Mode 1 for 10 min after every power cycle and 10 min after S button pressed.


Settings in progress

Factory reset and reboot

During factory reset, the LED will turn solid green for approx. 1sec, then the blue and red LED will be blinking 0,1s On, 0,1s Off for about 2sec.

Adding / Removing

During adding or removing, the LED will be blinking blue in Mode 2.

Firmware updating OTA

During the OTA update, the LED will be blinking blue and red in Mode 2.

Checking power supply 230 V AC frequency or 24 V DC voltage

During checking the power supply, the LED will be blinking blue and red in Mode 5.

Settings mode with S button

Adding / Removing menu selected

When the menu is selected the LED will be on blue, for maximum of 10 seconds.

Adding / Removing menu - while pressing S- button - Add/Remove process selected

When the menu is executing the LED will be blinking blue in Mode 3.

Factory reset menu selected

When the menu is selected the LED will be on red, for maximum of 10 seconds.

Factory reset - while pressing S - button - Factory reset process selected

When the menu is executing the LED will be blinking red in Mode 3.

Alarm Mode

Over-current detected

The LED will be blinking red in Mode 4 1x - 0,2s On 0,2s Off 2s Off and repeating this sequence

Overheat detected

The LED will be blinking red in Mode 4 - 2x (LED 0,2s On / 0,2s Off) + 2s Off and repeating this sequence

Power supply fault (power supply 230 V AC frequency or 24 V DC voltage fault)

The LED will be blinking red in Mode 4 - 3x (LED 0,2s On / 0,2s Off) + 2s Off and repeating this sequence

LED blinking modes

Click to see the LED blinking modes

LED blinking modes

Mode 1

0,5s On/2s Off

Mode 2

0,5s On/0,5s Off

Mode 3

0,1s On/0,1s Off

Mode 4

(1x to 6x - 0,2s On/0,2s Off) + 2s Off

Mode 5

0,2s On blue/0,2s On red

Specifications

Power supply

110-240 V AC / 24 V DC +/- 10%

Power consumption

< 0.3 W

Power measurement [W]

Yes

Max switching voltage AC

240 V

Max switching current AC

10 A per channel, 16 A total, 18 A total peak

Max switching voltage DC

30 V

Max switching current DC

10 A

Overheating protection

Yes

Over-current protection

Yes

Over-voltage protection

Yes

Distance

up to 40 m indoors (131 ft.) (depends on local condition)

Z-Wave® repeater:

Yes

CPU

Z-Wave® S800

Z-Wave® frequency band:

868,4 MHz

Maximum radio frequency power transmitted in frequency bend(s)

< 25 mW

Size (H x W x D)

37 x 42 x 16 ± 0.5 mm / 1.46 x 1.65 x 0.63 ± 0.02 in

Weight

29g

Mounting

Wall console

Screw terminals max torque

0.4 Nm / 3.5 lbin

Conductor cross section

0.5 to 1.5 mm? / 20 to 16
AWG

Conductor stripped length

5 to 6 mm / 0.20 to 0.24 in

Shell material

Plastic

Colour

Black

Ambient temperature

-20°C to 40°C / -5°F to 105°F

Humidity

30% to 70% RH

Max. altitude

2000 m / 6562 ft.

Basic wiring diagram

Fig.1

Fig. 2

Fig. 3

Fig. 4

Legend

Terminals

Wires

N

Neutral terminal

N

Neutral wire

L

Live terminal (110–240 V AC)

L

Live (110 - 240 V AC) wire

SW 1

Switch/push-button input terminal (controlling O1)

+

24 V DC positive wire

SW 2

Switch/push-button input terminal (controlling O2)

GND

24 V DC ground wire

O1

Load circuit 1 output terminal

O2

Load circuit 2 output terminal

+

24 V DC positive terminal

?

24 V D