Wave 1PM (EU)
Note: The product line known as "Shelly Qubino Wave" will now be referred to as "Shelly Wave". This name change will not impact the functionality of any devices. The only modification will be the use of the new name in all future documentation.
Device identification
Device: Wave 1PM
EU Part number/Ordering Code: QNSW-001P16EU
Z-Wave Product type ID: 0x0002
Z-Wave Product ID: 0x0084
Z-Wave Manufacturer: Shelly Europe Ltd.
Z-Wave Manufacturer ID: 0x0460
Terminology
Device - In this document, the term "Device" is used to refer to the Shelly Qubino device that is a subject of this guide.
Gateway - A Z-Wave(r) gateway, also referred to as a Z-Wave(r) controller, Z-Wave(r) main controller, Z-Wave(r) primary controller, or Z-Wave(r) hub, etc., is a device that serves as a central hub for a Z-Wave(r) smart home network. The term "gateway" is used in this document.
S button - The Z-Wave(r) Service button, located on Z-Wave(r) devices and is used for various functions such as adding (inclusion), removing (exclusion), and resetting the device to its factory default settings. The term "S button" is used in this document.
Short description
The Device is a single product that enables the control of the on/off function for one electrical device such as bulb, ceiling fan, IR heater. It measures power consumption of the connected device. The Device is compatible with switches (default) and push-buttons.
Switch connected to input terminal SW (SW1)
If the SW (SW1) is configured as a switch (default), each toggle of the switch will change the output state O (O1) to the opposite state - ON, OFF, ON, etc.
Change switch position once: Change the state of the output state O (O1) to the opposite one and send command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association)
Main applications
Residential
MDU (Multi Dwelling Units - apartments, condominiums, hotels, etc.)
Light commercial (small office buildings, small retail/restaurant/gas station, etc.)
Government/municipal
University/college
Integrations
Shelly Qubino Wave devices are developed on the world's leading technology for smart homes - Z-Wave.
This means Shelly Qubino Wave works with all certified gateways supporting Z-Wave communication protocol.
To make sure the functions of Shelly Qubino Wave products are supported on your gateway, we are regularly executing compatibility tests of our devices with different Z-Wave gateways.
Simplified internal schematics
Device electrical interfaces
Inputs
1 switch/button input on screw terminal
5 power supply inputs on screw terminals: 2 N (+) and 3 L ()
Outputs
1 relay output with power measurement on screw terminal
Connectivity
Z-Wave - Unsecure, S0 Security, S2 Unauthenticated Security, S2 Authenticated Security
Safety features
Overheat protection
switch off its own relay
sends the Notification Report to the Gateway (Overheat detected)
the led lights react as specified above (check blinking mode for Overheat detected)
Any of next activities reset this alarm: power cycle, short press on S button, press any switch-push button connected to any SW (SW, SW1, SW2, ...) terminal.
NOTE: The Overheat protection is always active and cannot be disabled.
Additional description above under chapter Notification for Overheat detected.
Over-current Protection
Device has internal Over-current protection. If the current exceeds 16A+10% (Max switching current +10%) for more than 5s, the Device will:
switch off its own relay
sends the Notification Report to the Gateway (Over-current detected)
the led lights react as specified above (check blinking mode for Over-current detected)
Any of next activities reset this alarm: power cycle, short press on S button, press any switch-push button connected to any SW (SW, SW1, SW2, ...) terminal.
NOTE: The Over-current protection is always active and cannot be disabled.
Additional description above under chapter Notification for Over-current detected.
Supported load types
Resistive (incandescent bulbs, heating devices)
Capacitive (capacitor banks, electronic equipment, motor start capacitors)
Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)
User interface
S button and operating modes
Normal mode
Setting in progress mode
-
Setting mode (with S button)
Settings mode is required to start desired procedure for example: adding (inclusion), removing (exclusion), factory reset etc. It has a limited time of operation. After the procedure in Setting mode is concluded, the Device goes automatically into Normal mode.
-
Entering to Setting mode:
Quickly press and hold the S button on the Device until the LED turns solid blue
An additional quick press on the S button means menu change in infinite loop
Menu LED status has a timeout of 10s before entering again into Normal state
S button's functions
Manually adding the Device to a Z-Wave network
Manually removing the Device from a Z-Wave network
Factory Reset the Device
LED Signalisation
LED blinking modes
Specifications
Power supply |
110-240 V AC / 24-30 V DC |
Power consumption |
< 0.3 W |
Power measurement (W) |
Yes |
Max. switching voltage AC |
240 V |
Max. switching current AC |
16 A |
Max. switching voltage DC |
30 V |
Max. switching current DC |
10 A |
Overheating protection |
Yes |
Overload protection |
Yes |
Distance |
Up to 40 m indoors (131 ft.) (depends on local condition) |
Z-Wave(r) repeater |
Yes |
CPU |
Z-Wave(r) S800 |
Z-Wave(r) frequency bands |
868,4 MHz |
Maximum radio frequency power transmitted in frequency band(s) |
< 25 mW |
Size (H x W x D) |
37x42x16 +-0.5 mm / 1.46x1.65x0.63 +-0.02 in |
Weight |
27 g / 0.95 oz. |
Mounting |
Wall console |
Screw terminals max. torque |
0.4 Nm / 3.5 lbin |
Conductor cross section |
0.5 to 1.5 mm2 / 20 to 16 AWG |
Conductor stripped length |
5 to 6 mm / 0.20 to 0.24 in |
Shell material |
Plastic |
Colour |
Red |
Ambient temperature |
-20degC to 40degC / -5degF to 105degF |
Humidity |
30% to 70% RH |
Max. altitude |
2000 m / 6562 ft. |
Basic wiring diagram
Legend
Terminals |
Wires |
||
---|---|---|---|
N |
Neutral terminal |
N |
Neutral wire |
L |
Live terminal (110-240 V AC) |
L |
Live (110 - 240 VAC) wire |
SW |
Switch/push-button input terminal (controlling O) |
+ |
24 - 30 V DC positive wire |
O |
Load circuit output terminal |
GND |
24 - 30 V DC ground wire |
+ |
24 - 30 V DC positive terminal |
|
|
24 - 30 V DC ground terminal |