Wave Pro 2PM

Wave Pro 2PM (EU)

Note: The product line known as "Shelly Qubino Wave" will now be referred to as "Shelly Wave". This name change will not impact the functionality of any devices. The only modification will be the use of the new name in all future documentation.

wave_pro_2PM_160x350.jpg

Device identification

Device: Wave Pro 2PM
EU Part number/Ordering Code: QPSW-0A2P16EU
Z-Wave Product type ID: 0x0002
Z-Wave Product ID: 0x008D
Z-Wave Manufacturer: Shelly Europe Ltd.
Z-Wave Manufacturer ID: 0x0460

Terminology

  • Device - In this document, the term “Device” is used to refer to the Shelly Qubino device that is a subject of this guide.

  • Gateway - A Z-Wave® gateway, also referred to as a Z-Wave® controller, Z-Wave® main controller, Z-Wave® primary controller, or Z-Wave® hub, etc., is a device that serves as a central hub for a Z-Wave® smart home network. The term “gateway” is used in this document.

  • S button - The Z-Wave® Service button, located on Z-Wave® devices and is used for various functions such as adding (inclusion), removing (exclusion), and resetting the device to its factory default settings. The term "S button" is used in this document.

Short description

The Device is a DIN rail mountable 2-channel smart switch with power measurement. It controls the on/off function for two independent electrical devices with a load up to 16 A per channel (25 A in total). It is compatible with switches (default) and push-buttons.

Switch/push-button connected to input terminal SW (SW1)

SW1: If the SW (SW1) is configured as a switch (default), each toggle of the switch will change the output O (O1) state to the opposite state - on, off, on, etc. If the SW (SW1) is configured as a push-button in the Device settings, each press of the push-button will change the output O (O1) state to the opposite state - on, off, on, etc.

Switch connected to input terminal SW (SW1)

If the SW (SW1) is configured as a switch (default), each toggle of the switch will change the output O (O1) state to the opposite state - on, off, on, etc.

  • Change switch position once: Change the state of the output O (O1) state to the opposite state and send the command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association).

  • Change switch position twice: If the delay between the first in the second click is less then 500ms, this is interpreted as “Change the switch position twice”. Send command to the associated devices (dimmers, shutters,….) in associated groups 2 and 3 (check chapter Z-Wave Association).

Switch-memory connected to input terminal SW (SW1)

If the SW (SW1) is configured as a switch-memory, than:

  • Switching to Close switch-memory contact: Change the state of the output state O (O1) to the On state and send command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association)

  • Switching to Open switch-memory contact: Change the state of the output state O (O1) to the Off state and send command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association)

Push-button connected to input terminal SW (SW1)

If the SW (SW1) is configured as a push-button in the Device settings, each press of the push-button changes the output state O (O1) to opposite - ON, OFF, ON, etc.

  • Short press: Change the state of the output state O (O1) to the opposite one and send command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association)

  • Hold: Send command to the associated devices in associated group 3 (check chapter Z-Wave Association)

  • Release: Send command to the associated devices in associated group 3 (check chapter Z-Wave Association)

Switch/push-button connected to input terminal SW2

If the SW2 is configured as a switch (default), each toggle of the switch will change the output O2 state to the opposite state - on, off, on, etc. If the SW2 is configured as a push-button in the Device settings, each press of the push-button will change the output O2 state to the opposite state - on, off, on, etc.

Switch connected to input terminal SW2

If the SW2 is configured as a switch (default), each toggle of the switch will change the output state O2 to the opposite state - ON, OFF, ON, etc.

  • Change switch position once: Change the state of the output state O2 to the opposite one and send command to the associated devices in associated groups 4 and 5 (check chapter Z-Wave Association)

  • Change switch position twice: If the delay between first in second click is less then 500ms, this is interpreted as Change switch possition twice. Send command to the associated devices (dimmers, shutters,….) in associated groups 4 and 4 (check chapter Z-Wave Association)

Switch-memory connected to input terminal SW2

If the SW2 is configured as a switch-memory, than:

  • Switching to Close switch-memory contact: Change the state of the output state O2 to the On state and send command to the associated devices in associated groups 4 and 5 (check chapter Z-Wave Association)

  • Switching to Open switch-memory contact: Change the state of the output state O2 to the Off state and send command to the associated devices in associated groups 4 and 5 (check chapter Z-Wave Association)

Push-button connected to input terminal SW2

If the SW2 is configured as a push-button in the Device settings, each press of the push-button changes the output state O2 to opposite - ON, OFF, ON, etc.

  • Short press: Change the state of the output state O2 to the opposite one and send command to the associated devices in associated groups 4 and 5 (check chapter Z-Wave Association)

  • Hold: Send command to the associated devices in associated group 4 (check chapter Z-Wave Association)

  • Release: Send command to the associated devices in associated group 5 (check chapter Z-Wave Association)

Switching On/Off load connected to O (O1

Load connected to O (O1) is possible to switch On/Off by:

  • by Z-Wave command

  • Automatically switching can be enabled by proper Parameters No. 19 and 20 settings.

  • pressing the switch/push-button SW (SW1): Change the state of the connected load to the opposite one

Switching On/Off load connected to O2

Load connected to O2 is possible to switch On/Off by:

  • by Z-Wave command

  • Automatically switching can be enabled by proper Parameters No. 21 and 22 settings.

  • pressing the switch/push-button SW2: Change the state of the connected load to the opposite one

Main applications

  • Residential

  • MDU (Multi Dwelling Units - apartments, condominiums, hotels, etc.)

  • Light commercial (small office buildings, small retail/restaurant/gas station, etc.)

  • Government/municipal

  • University/college

Integrations

Shelly Qubino Wave devices are developed on the world's leading technology for smart homes – Z-Wave.

This means Shelly Qubino Wave works with all certified gateways supporting Z-Wave communication protocol.

To make sure the functions of Shelly Qubino Wave products are supported on your gateway, we are regularly executing compatibility tests of our devices with different Z-Wave gateways.

Simplified internal schematics

Shelly Pro 2PM V2 internal schematics

Device electrical interfaces

Inputs

  • 2 switch/button input on screw terminal

  • 3 power supply inputs on screw terminals: N (+), L (?)

Outputs

  • 2 relay output with power measurement on screw terminal

Connectivity

Z-Wave - Unsecure, S0 Security, S2 Unauthenticated Security, S2 Authenticated Security

Safety features

Overheat protection

Device has internal Overheat protection. If the temperature exceeds predefined values 80°C for more than 5s, the Device will:

  • switch off its own relay

  • sends the Notification Report to the Gateway (Overheat detected)

  • the LED lights react as specified above (check LED blinking mode for Overheat detected)

Any of the following activities reset this alarm: power cycle, short press on the S button, press on any switch/push-button connected to any SW (SW, SW1, SW2, …) terminal.

NOTE: The Overheat protection is always active and cannot be disabled.
Additional description above under chapter Notification for Overheat detected.

Over-current Protection

Device has internal Over-current protection. If the current exceeds 16A+10% (Max switching current +10%) for more than 5s, the Device will:

  • switch off its own relay

  • sends the Notification Report to the Gateway (Over-current detected)

  • the LED lights react as specified above (check LED blinking mode for Over-current detected)

Any of the following activities reset this alarm: power cycle, short press on the S button, press on any switch/push-button connected to any SW (SW, SW1, SW2, …) terminal.

NOTE: The Over-current protection is always active and cannot be disabled.
Additional description above under chapter Notification for Over-current detected.

Over-voltage Protection

Device has internal Over-voltage protection. This is valid for standard power supply voltage 230 V AC. If the voltage exceeds 240 V AC+15% (278 V AC) for more than 5s, the Device will:

  • switch off its own relay

  • sends the Notification Report to the Gateway (Over-voltage detected)

  • the LED lights react as specified above (check LED blinking mode for Over-voltage detected)

Any of the following activities reset this alarm: power cycle, short press on the S button, press on any switch/push-button connected to any SW (SW, SW1, SW2, …) terminal.

NOTE: The Over-current protection is always active and cannot be disabled.
Additional description above under chapter Notification for Over-voltage detected.

Supported load types

  • Resistive (incandescent bulbs, heating devices)

  • Capacitive (capacitor banks, electronic equipment, motor start capacitors)

  • Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)

User interface

S button and operating modes

  1. Normal mode

  2. Setting in progress mode

  3. Setting mode (with S button)

    • Settings mode is required to start desired procedure for example: adding (inclusion), removing (exclusion), factory reset etc. It has a limited time of operation. After the procedure in Setting mode is concluded, the Device goes automatically into Normal mode.

    • Entering to Setting mode:

      • Quickly press and hold the S button on the Device until the LED turns solid blue

      • An additional quick press on the S button means menu change in infinite loop

      • Menu LED status has a timeout of 10s before entering again into Normal state

S button’s functions

  • Manually adding the Device to a Z-Wave network

  • Manually removing the Device from a Z-Wave network

  • Factory Reset the Device

LED Signalisation

Click to see LED signalisation
Normal mode

Removed/Excluded

The LED will be blinking blue in Mode 1 for 10 min after every power cycle and 10 min after S button pressed.

Added/Included

The LED will be blinking green in Mode 1 for 10 min after every power cycle and 10 min after S button pressed.


Settings in progress

Factory reset and reboot

During factory reset, the LED will turn solid green for approx. 1sec, then the blue and red LED will be blinking 0,1s On, 0,1s Off for about 2sec.

Adding / Removing

During adding or removing, the LED will be blinking blue in Mode 2.

Firmware updating OTA

During the OTA update, the LED will be blinking blue and red in Mode 2.

Checking power supply 230 V AC frequency or 24 V DC voltage

During checking the power supply, the LED will be blinking blue and red in Mode 5.

Settings mode with S button

Adding / Removing menu selected

When the menu is selected the LED will be on blue, for maximum of 10 seconds.

Adding / Removing menu - while pressing S- button - Add/Remove process selected

When the menu is executing the LED will be blinking blue in Mode 3.

Factory reset menu selected

When the menu is selected the LED will be on red, for maximum of 10 seconds.

Factory reset - while pressing S - button - Factory reset process selected

When the menu is executing the LED will be blinking red in Mode 3.

Alarm Mode

Over-current detected

The LED will be blinking red in Mode 4 1x - 0,2s On 0,2s Off 2s Off and repeating this sequence

Overheat detected

The LED will be blinking red in Mode 4 2x - 0,2s On 0,2s Off 0,2s On 0,2s Off 2s Off and repeating this sequence

Power supply fault (power supply 230 V AC frequency or 24 V DC voltage fault)

The LED will be blinking red in Mode 4 3x - 0,2s On 0,2s Off 0,2s On 0,2s Off 0,2s On 0,2s Off 2s Off and repeating this sequence

Overvoltage detected

The LED will be blinking red in Mode 4 7x - 0,2s On 0,2s Off 0,2s On 0,2s Off 0,2s On 0,2s Off 0,2s On 0,2s Off 0,2s On 0,2s Off 0,2s On 0,2s Off 0,2s On 0,2s Off 2s Off and repeating this sequence

LED blinking modes

Click to see the LED blinking modes

LED blinking modes

Mode 1

0,5s On/2s Off

Mode 2

0,5s On/0,5s Off

Mode 3

0,1s On/0,1s Off

Mode 4

(1x to 6x - 0,2s On/0,2s Off) + 2s Off

Mode 5

0,2s On blue/0,2s On red

Specifications

Power supply

110 - 240 V AC, 50/60 Hz

Power consumption

< 0.3 W

Power measurement [W]

Yes

Max. switching voltage AC

240 V

Max. switching current AC

16 A per channel, 25 A total

Max. switching voltage DC

N/A

Max. switching current DC

N/A

Overheating protection

Yes

Overload protection

Yes

Overvoltage protection

Yes

Distance

Up to 40 m indoors (131 ft.) (depends on local condition)

Z-Wave® repeater:

Yes

CPU

Z-Wave® S800

Z-Wave® frequency band:

868,4 MHz

Maximum radio frequency power transmitted in frequency band(s)

< 25 mW

Size (H x W x D)

94x19x69 ±0.5 mm / 3.70x0.75x2.71 ±0.02 in

Weight

75 g / 2.65 oz.

Mounting

DIN rail

Screw terminals max. torque

0.4 Nm / 3.54 lbin

Conductor cross section

0.5 to 2.5 mm? / 20 to 14 AWG (green connector)
0.5 to 1.5 mm? / 20 to 16 AWG (white connectors)

Conductor stripped length

6 to 7 mm / 0.24 to 0.28 in (green connector)
5 to 6 mm / 0.20 to 0.24 in (white connectors)

Shell material

Plastic

Color

Black

Ambient temperature

-20°C to 40°C / -5°F to 105°F

Humidity

30% to 70% RH

Max. altitude

2000 m / 6562 ft.

Basic wiring diagram

01_Wiring_diagram_Wave_Pro_2PM-170X300.jpg

Legend