Shelly EM Gen3
Device identification
Device name: Shelly EM Gen3
Device model: S3EM-002CXCEU
Device SSID: ShellyEMG3-XXXXXXXXXXXX
BLE Model ID: 0x1027
Short description
Shelly EM Gen3 (the Device) is a small form factor smart energy meter using up to 2 current transformers (contactless metering), which allows energy metering the consumption of electric appliances and reporting to a mobile phone, tablet, PC, or home automation system. It can work standalone in a local Wi-Fi network or it can also be operated through cloud home automation services. The Device has internal storage for data allowing for later retrieval. The Device has single dry contact switch for controlling external loads.
Shelly EM Gen3 can be accessed, controlled, and monitored remotely from any place where the User has internet connectivity, as long as the device is connected to a Wi-Fi access point and the Internet.
Shelly EM Gen3 can be retrofitted into standard electrical wall boxes, next to electrical appliances, power sockets, or in other places with limited installation space.
Shelly EM Gen3 has an embedded Web Interface which can be used to monitor, configure, and control the device.
Main features
Compact form factor
Single phase, two channels measurment
Current transformer connection
Dry contact relay for contactor control
Real-time clock
Data logs stored on device for up to 10 days of minute data records
Use cases
Power Consumption Monitoring: Monitor the power consumption of connected devices in real-time. This information can be valuable for understanding energy usage patterns and making informed decisions to reduce consumption.
Energy Efficiency Optimization: Identify electrical energy consumption patterns and optimize electricity usage.
Appliance Health Check: Keep track of the power usage of individual appliances to assess their health and performance over time. Sudden spikes or changes in power consumption may indicate issues with the appliance.
Cost Management: With the knowledge of power consumption, you can estimate the cost of running specific devices and manage your electricity expenses more effectively.
Space-Efficient Retrofitting: Integrate the device into standard electrical wall boxes, behind power sockets, light switches, or other locations with limited space.
Remote Monitoring: Shelly EM Gen3 supports publishing data to Shelly cloud or other cloud based data collection and storage systems. This allows you to monitor power consumption even when you're away from home.
Local Monitoring: Like the rest of the Shelly Wi-Fi line of devices Shelly EM Gen3 allows for local only monitoring and automations. Access stored energy consumption records directly from the device UI. Automate locally with rules based on instantaneous power consumption or energy consumer for a period of time.
Main applications
Residential
MDU (Multi Dwelling Units - apartments, condominiums, hotels, etc.)…
Light commercial (small office buildings, small retail/restaurant/gas station, etc.)…
Industrial (factories, power plants, water processing, refineries, etc.)…
Government/municipal
University/college
Farming
Simplified internal schematics
Connectivity
Wi-Fi
Bluetooth
Protocols
MQTT
HTTP
WebSocket
RPC
Safety function
Internal temperature sensing and reporting
Supported load types
Resistive (incandescent bulbs, heating devices)
Capacitive (LED light drivers, capacitor banks, electronic equipment, motor start capacitors)
Inductive (transformers, fans, refrigerators, air-conditioners)
User interface
Inputs
-
One (Control) button
Press and hold for 5 seconds to enable Device access point and Bluetooth connection.
Press and hold for 10 seconds to factory reset the Device.
Outputs
-
LED (monocolor) indication
AP (Access Point) enabled and Wi-Fi disabled:
1 secondON
/ 1 secondOFF
Wi-Fi enabled, but not connected to a Wi-Fi network:
1 secondON
/ 3 secondsOFF
Connected to a Wi-Fi network:
ConstantlyON
Cloud is enabled, but not connected:
1 secondON
/5 secondsOFF
Connected to Shelly Cloud:
ConstantlyON
OTA (Over the Air Update):
½ secON
/ ½ secondOFF
Button pressed and held for 5 seconds:
½ secondON
/ ½ secondOFF
Button presses and held for 10 seconds:
¼ secondON
/ ¼ secondOFF
The list above starts with the initial device status and the lowest priority. Every next state cancels the previous one.
Specifications
Quantity |
Value |
---|---|
Physical | |
Size (HxWxD): |
37x42x16 mm / 1.46x1.65x0.63 inch |
Weight: |
|
Screw terminals max torque: |
0.4 Nm / 3.5 lbin |
Conductor cross section: |
0.2 to 2.5 mm² / 24 to 14 AWG (solid, stranded, and bootlace ferrules) |
Conductor stripped length: |
6 to 7 mm / 0.24 to 0.28 in |
Mounting: |
Wall console, Electrical cabinet |
Shell material: |
Plastic |
Shell color: |
|
Connectors color: |
Black |
Environmental | |
Ambient working temperature: |
-20 °C to 40 °C / -5 °F to 105 °F |
Humidity: |
30 % to 70 % RH |
Max. altitude: |
2000 m / 6562 ft |
Electrical | |
Power supply: |
110 - 240 V~ 50/60 Hz |
Power consumption: |
< 1.2 W |
Neutral not needed: |
Yes or No |
External protection: |
2 A, tripping characteristic B or C, |
Output circuits ratings | |
Max. switching voltage: |
240 V~ |
Max. switching current: |
2 A/240 V~ |
Sensors, meters | |
Voltmeter (AC): |
110-240 V~ 50/60 Hz |
Voltmeter accuracy: |
±2% |
Ammeter (AC): |
0 - 80A |
Ammeter accuracy: |
±2 % (2 - 50 A), ±2 % (1 - 2 A), ±5 % (0 - 1 A) |
Compatible current transformers: |
|
Power and energy meters: |
|
Channel-to-channel calibration minimum load: |
500 W |
No load threshold: |
30 VA per channel |
Measurement data storage: |
At least 10 days of 1 min data resolution |
Data export: |
|
Internal-temperature sensor: |
Yes |
Radio | |
Wi-Fi | |
Protocol: |
802.11 b/g/n |
RF band: |
2412 - 2472 МHz |
Max. RF power: |
< 20 dBm |
Range: |
Up to 30 m / 100 ft indoors and 50 m / 160 ft outdoors |
Bluetooth | |
Protocol: |
4.2 |
RF band: |
2402 - 2480 MHz |
Max. RF power: |
< 4 dBm |
Range: |
Up to 10 m / 33 ft indoors and 30 m / 100 ft outdoors |
Microcontroller unit | |
CPU: |
ESP-Shelly-C38F |
Flash: |
8 MB |
Firmware capabilities | |
Schedules: |
Yes |
Webhooks (URL actions): |
20 with 5 URLs per hook |
Scripting: |
Yes |
MQTT: |
Yes |
Encryption: |
Yes (Transport level) |
Authentication: |
Yes (Application and transport level) |
Basic wiring diagrams
Legend
Terminals |
Wires |
||
---|---|---|---|
O |
Load circuit output terminal |
L |
Live (110-240 V) wire |
I |
Load circuit input terminal |
N |
Neutral wire |
IA |
First channel current transformer input |
Current transformers |
|
IB |
Second channel current transformer input |
CTA |
First channel current transformer |
L |
Live (110-240 V) terminal |
CTB |
Second channel current transformer |
N |
Neutral terminal |
Troubleshooting
-
Check the correct installation of the CT:
If negative readings on a measured circuit are read and are not expected, check the correct installation of the CT (K->L).
-
Ensure that the device is properly powered:
Check power cables, outlets, and any power indicators on the device.
-
Inspect Connections:
Verify that all connections, including cables and wiring, are secure and properly seated. Loose connections can lead to functionality issues.
-
Review Device Settings:
If applicable, check and review the device settings. Ensure that configurations are correct and match your intended use.
-
Update Firmware/Software:
Check if there are any available firmware or software updates for the device. Keeping the device up-to-date can resolve known issues and improve performance.
-
Restart or Reboot:
Sometimes, a simple restart can resolve temporary glitches. Turn off the device, wait a few seconds, and then power it back on.
-
Check Network Connection:
If the device is connected to a network, ensure that the network settings are correct. Test the network connection and consider restarting routers or switches if needed.
-
Inspect Physical Components:
Physically inspect the device for any signs of damage, overheating, or unusual behavior.
-
Check Compatibility:
Ensure that the device is compatible with other components in your system, including hardware and software. Incompatibility issues can lead to malfunctions.
-
Monitor Environmental Factors:
Consider environmental factors such as temperature and humidity.
-
Inspect Power Supply Quality:
Poor power quality, including voltage spikes or fluctuations, can affect device performance. Consider using a surge protector or voltage regulator if needed.
*These are general troubleshooting steps, and the specific steps may vary based on the type of device or issue you are facing. If the issue persists and you are unable to resolve it, consider reaching out to our technical customer support.
Components and APIs
Coming soon
Compliance
Shelly EM Gen3 multilingual EU declaration of conformity.pdf
Printed user guide
Shelly EM Gen3 multilingual printed user and safety guide.pdf